BA
|
Operating mode*
|
Operating mode:
|
PU
|
Surplus*
|
PV surplus, a positive value
means PV surplus. |
| LZ |
Running time hours |
Running time in hours. If the output FV is on, the running time is
added up until this time is reached.
|
| SM |
Start manual |
With a positive edge at this input the consumer is switched on for the
remaining running time. This input can be activated, for example,
with a time switch. When the remaining time has elapsed,
the connected variable is set to 0, so with the time switch
only a 1 needs to be set. |
| RS |
Reset |
Manual reset of the remaining running time. With a positive edge the
remaining running time is set to 0. |
| FG |
Enable external |
Optional external enable. If this input is not assigned,
the control is always enabled. Otherwise the control is only
enabled when a value other than 0 is present at the input. This
input can be used to halt the control when, for example,
another consumer is to have priority. |
FV
|
Enable
consumer
|
Enable consumer |
LA
|
Running time
current
|
Running time with surplus
|
| LR |
Running time remaining |
Running time remaining |
|
Power
consumer
|
Power of the consumer |
|
Time
control
|
Time in which it is checked whether
surplus is present and the consumer is switched on/off.
|
|
Minimum
surplus
|
Minimum surplus that must at least be
present for the control to begin. |
|
Autom. reset hour |
Time at which the running time is reset. 0 means the running time is
reset at 0:00h. |