| S1 |
Switch 1 |
Switches the relay. The effect depends on the corresponding parameter, see below. |
| S2 |
Switch 2 |
Switches the relay. The effect depends on the corresponding parameter, see below. |
| S3 |
Switch 3 |
Switches the relay. The effect depends on the corresponding parameter, see below. |
| S4 |
Switch 4 |
Switches the relay. The effect depends on the corresponding parameter, see below. |
| S1 |
Switch 1 status |
State of the push-button or switch 1 connected to the device. |
| S2 |
Switch 2 status |
State of the push-button or switch 2 connected to the device. |
| S3 |
Switch 3 status |
State of the push-button or switch 3 connected to the device. |
| S4 |
Switch 4 status |
State of the push-button or switch 4 connected to the device. |
| R1 |
Relay 1 status |
Actual state of the relay 1 in the device. Is also updated when switching via the Shelly app or the push-button at the device. |
| R2 |
Relay 2 status |
Actual state of the relay 2 in the device. Is also updated when switching via the Shelly app or the push-button at the device. |
| R3 |
Relay 3 status |
Actual state of the relay 3 in the device. Is also updated when switching via the Shelly app or the push-button at the device. |
| R4 |
Relay 4 status |
Actual state of the relay 4 in the device. Is also updated when switching via the Shelly app or the push-button at the device. |
| P1 |
Relay 1 power |
Present active power in watts. |
| P2 |
Relay 2 power |
Present active power in watts. |
| P3 |
Relay 3 power |
Present active power in watts. |
| P4 |
Relay 4 power |
Present active power in watts. |
|
MQTT topic |
Topic of the device, exactly as in the MQTT settings of the device. Example: shellypro4pm-AABBCCDDEEFF |
|
Switch 1 |
Behaviour of the corresponding input. Toggle (rising edge) for push-buttons: every change from 0 to 1 toggles the relay. Toggle (1/0) for switches and for control from the program: the value is applied directly. |
|
Switch 2 |
Behaviour of the corresponding input. Toggle (rising edge) for push-buttons: every change from 0 to 1 toggles the relay. Toggle (1/0) for switches and for control from the program: the value is applied directly. |
|
Switch 3 |
Behaviour of the corresponding input. Toggle (rising edge) for push-buttons: every change from 0 to 1 toggles the relay. Toggle (1/0) for switches and for control from the program: the value is applied directly. |
|
Switch 4 |
Behaviour of the corresponding input. Toggle (rising edge) for push-buttons: every change from 0 to 1 toggles the relay. Toggle (1/0) for switches and for control from the program: the value is applied directly. |