KLF 200 / VELUX| This
function block controls VELUX io-homecontrol actuators (roller
shutters, windows, awnings, venetian blinds, gates, lights) through
the VELUX KLF 200 gateway and reads back their positions. Communication uses the local KLF 200 API (TCP port 51200, TLS-encrypted). Enter the IP address and password of the KLF 200. The password is the setup key printed on the device (Wi-Fi password). Set the number of actuators and generate the variables. Alternatively, when the controller is connected, the Search actuators button can read and import the available actuators automatically. Three addresses are created per actuator:
Note: The automatic search only works if the controller is connected to the software and is itself connected to the KLF 200. If the system is operated via APP, special protective measures should be taken (e.g. a private VPN access). The system should never be freely accessible from the internet. |
Outputs |
||
| ER |
Error counter |
Number of communication errors (-1 = software without SSL support) |
Parameters |
||
| IP address |
IP address of the KLF 200 | |
| Port |
TCP port of the KLF 200 API (default: 51200) | |
| Password |
Setup key of the KLF 200 (printed on the device) | |
| Timeout (ms) |
Connection timeout in milliseconds | |
| Number of actuators |
Number of actuators to control (determines the number of generated addresses) | |
| Actuator list |
Assignment of the actuators (NodeID/name/type). Filled automatically by the search. | |
| Debug |