Overview Block Meter

This control element shows a meter: the consumption from today up to the year with a comparison to the previous period, the costs and the history as bars. For water it also shows the water protection with valve, leak sensors and the current draw-off. It belongs to the function block Block Meter and is only available in the new block design.

Operation

The tile

  1. Symbol and name: the symbol shows the medium. Below the name is the current flow or power, in case of a message its reason in red.
  2. Today: today's consumption in large print, to its right the change compared with yesterday in percent (▲ more, ▼ less).
  3. Three columns: yesterday, the current month and the costs of the month (without costs the current year).
  4. Bars: the consumption of the last six days (grey) and of today (coloured, far right, with its value above), with the weekday below. The highest of these seven days fills the full height, the others are shown in proportion. Today's bar grows during the day, so in the morning it is usually still low.

Tapping the bars opens the history directly, tapping the rest of the tile opens the overview. If -.-- is shown instead of a number, no data is available yet.

On a low, wide tile (less than 180 pixels high) yesterday, month and costs are on the right and the bars in the footer. For water with water protection the footer there shows the valve, the leak sensors and the current draw-off instead of the bars – red or coloured when active.

Symbol: in the Studio a different symbol for the tile and the dialogs can be chosen under Icon. Only the symbols of the program are offered, so that they adapt to the style; if left empty, the symbol of the medium is used.

The overview

  1. Messages: shown at the top as soon as a rule has triggered or the valve is closed. Acknowledge resets the messages and opens the valve – unless a leak sensor is still active.
  2. Meter: meter reading and flow or power, below it the way into the history.
  3. Consumption: today, yesterday, week, month and year, each with the value of the previous period. For gas, oil and pellets also the energy in kWh.
  4. Costs: if switched on in the settings.
  5. Water protection: valve, profile present or absent, the current and the last draw-off. Allow large draw-off suspends volume and duration per draw-off for a while, e.g. for the pool or the garden.
  6. Learning phase: observes the draw-offs for some days and then suggests limits (largest value × 1.5). They are only applied with Apply suggestion.
  7. More: log, settings, set meter reading and test mode.

The history

  1. Period: day (per hour), week and month (per day), year (per month) and years. The second bar selects the quantity: consumption or import, feed-in, energy or costs – it only appears if there is more than one.
  2. Summary line: the total of the period, the comparison period and the change in percent. In the running period the comparison only goes up to the same point in time ("previous year until now"); otherwise a month that has just begun would always be far below the whole month of the previous year.
  3. Chart: the period as bars, one per hour, day or month. The line above is the comparison period laid onto the same period – for day and week the previous week, for month and year the previous year. The chart can be moved and zoomed like the other charts.
  4. Arrows at the bottom: left one period back, right forward again.

The share symbol in the title bar passes the chart on as an image. Behind the gear are the export as a CSV file and Delete data (after a confirmation).

Set meter reading

Aligns the meter reading with the register of the meter. If Meter was replaced is switched on, the next value of the new meter becomes the base. Daily, monthly and yearly values remain in both cases, the action is written to the log.

Log

The last 32 events with time: which rule triggered, with value and limit, plus valve, acknowledge, meter replacement, overflow, discarded values, large draw-off and learning phase.

Test mode

Triggers an alarm for the set duration and, for water, closes the valve. Afterwards it opens again by itself.

Settings

Costs Prices from the project (default): tariff, current price and base fee come from the tariffs of the project and are only shown; for water the waste water tariff can be added. Without a matching tariff or for an exchange-based tariff the own prices apply. Own prices: energy price, single tariff or peak/off-peak by time or via input HT, base fee per month and the feed-in tariff. For gas the price is per kWh. The currency comes from the project.
Conversion to kWh Gas: calorific value and correction factor from the gas bill. Oil and pellets: heating value.
Monitoring Daily limit; deviation from the mean of the last 14 days with factor and minimum amount (at the earliest after one week); continuous consumption or base load at night: within the night window the set quiet time must occur once, otherwise it is reported; meter not sending (requires a meter that sends regularly); repeat alarm.
Water protection For each rule off, report or shut off: volume per draw-off (default present 300 l, absent 50 l), duration per draw-off (60 or 10 minutes), flow too high (3000 l/h for longer than 60 s), leak sensor. In addition the idle time after which a draw-off ends – choose it longer than the sending interval of the meter –, automatically absent without draw-off, the duration of the large draw-off, the waiting time for the valve feedback and the duration of the test mode.

A right-click on the control element in the Studio selects the block.