PS
|
ID pulse
|
Must be connected to the output „ID pulse“ of the EKEY UDP
block. A rising edge (new scan) triggers the evaluation.
|
ID
|
ID
|
Must be connected to the output „ID“ of the EKEY UDP
block. Provides the ID of the current scan, which is compared with the
stored IDs.
|
TR
|
Trigger
|
Triggered when the ID at the input matches one of the IDs
stored in the parameters. The type of output is determined by the
parameter „Trigger“.
|
|
Trigger
|
- Pulse: a pulse is output – the value „Output on“ for the „Pulse
time“, then „Output off“.
- Telegram 1: the value „Output on“ is output (only useful for KNX
systems).
- Toggle: on each trigger, the output toggles between „Output on“
and „Output off“.
|
|
Pulse time
|
Duration of the pulse in seconds (only for type „Pulse“,
default 5). |
|
Output on
|
Value output in the switched-on state (default 1). |
|
Output off
|
Value output in the switched-off state (default 0). |
|
ID 0 … ID 9
|
Up to 10 IDs the trigger should react to. An ID set to 0
is ignored. |